Pecron F5000LFP
5,120Wh, 7,200W AC, 240V. Compare current Amazon and eBay offers.
Specs. Street prices. One owned unit.
Affiliate disclosure. As an Amazon Associate we earn from qualifying purchases. As an eBay Partner Network participant we may earn a commission from qualifying purchases. Amazon and eBay are the only outbound shopping links on this site. Prices and availability change.
Home backup · 1800W · 240V · idle
Choose backup power around the appliances you need during an outage. Compare output, stored energy, voltage, and battery expansion, and account for the energy the inverter uses while switched on.
5,120Wh, 7,200W AC, 240V. Compare current Amazon and eBay offers.
31 tracked units publish at least 1800W AC or a 240V output. 6 list 240V. 21 list an expansion ceiling. Going above 1800W does not unlock new 120V appliances; it lets you run more compatible loads at once. Check each appliance's running and startup demand and required voltage; a dryer or water heater still needs true 240V. The Pecron F5000LFP is listed at 5,120Wh, 7,200W AC, 240V, expandable to 35,840Wh, 123.9 lb (manufacturer + retailer listings (pecron.com, Amazon B0GVMSFTXX, ShopSolar)).
The Solar Lab measured an Anker SOLIX F3800 drawing roughly 80W while idle in a simulated blackout — the pack was nearly dead by morning. Idle is the spec almost nobody prints and the one that decides whether a “weekend” unit lasts the night.
Start with the equipment you need, its running and starting power, and how long it must operate. Compare AC output and voltage first, then capacity, expansion options, and inverter idle draw. These tables use published specifications; they are not whole-home runtime tests.
For a single appliance, use the refrigerator runtime estimates. Once you have a capacity in mind, compare current price per watt-hour.
This is a specification comparison sorted by capacity. Suitability depends on your appliances, required voltage, starting power, and runtime. The methodology explains the calculations and sources.
These options show native or modular 240V paths recorded in the catalog, alongside different capacity and expansion choices. Confirm appliance voltage, running demand, startup demand, and any required hub or wiring before buying.
Large pack with 240V
Why it fits: 5,120Wh, 7,200W AC, verified 240V, and expansion to 35,840Wh cover a broad backup plan on paper.
Tradeoff: 123.9 lb is a substantial move and still does not replace checking each appliance's running/startup demand and voltage.
Current Amazon price is unavailable in the latest price check.
Modular 240V system
Why it fits: 3,600Wh and 3,600W AC make a substantial single-unit 120V base for a modular backup plan.
Tradeoff: 99 lb is still not a casual carry; the 240V setup requires two DELTA Pro units plus EcoFlow's Double Voltage Hub.
Voltage note: EcoFlow documents 240V as a two-unit setup with its Double Voltage Hub.
Current Amazon price: $1,899
Higher 240V output
Why it fits: 4,096Wh and 4,000W AC with verified 240V output provide more output headroom for a larger load list.
Tradeoff: 114 lb and the larger output/capacity make this a deliberate choice; verify startup demand first.
Current Amazon price: $2,799
See the full comparison table for every tracked model and the calculation notes.
A watt-hour (Wh) is stored energy: watts × hours. A 1,000Wh pack can theoretically supply 100W for 10 hours, or 50W for 20 hours. Real runtime is shorter once you count inverter loss and idle draw.
Hours below are estimates from capacity ÷ labeled average watts. They are not first-hand measurements of an appliance we ran. The pack size in the table is a published watt-hour rating, not a runtime we measured.
| Labeled average load | Estimated hours |
|---|---|
| 50W average | 102 h |
| 100W average | 51 h |
| 150W average | 34 h |
On a phone, swipe horizontally through the detailed comparison table.
| Model | Capacity Wh?A watt-hour (Wh) is stored energy: watts × hours. A 1,000Wh pack can theoretically supply 100W for 10 hours, or 50W for 20 hours. Real runtime is shorter once you count inverter loss and idle draw. Hours below are estimates from
| AC | 240V | Expandable to | Idle | Listings | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EcoFlow Delta Pro Ultra | 6,144Wh | 7,200W | Yes | 90,000Wh | — | |||||||||
| Pecron F5000LFP We own this | 5,120Wh | 7,200W | Yes | 35,840Wh | — | |||||||||
| EcoFlow Delta Pro 3 | 4,096Wh | 4,000W | Yes | 48,000Wh | — | |||||||||
| Pecron E3800LFP | 3,840Wh | 4,200W | Yes | 53,760Wh | — | |||||||||
| ABOK Ark3600 | 3,840Wh | 3,600W | No | 11,520Wh | — | |||||||||
| Bluetti Elite 400 | 3,840Wh | 2,600W | No | — | — | |||||||||
| EcoFlow Delta Pro | 3,600Wh | 3,600W | Yes | 25,000Wh | — | |||||||||
| Jackery HomePower 3600 Plus | 3,584Wh | 3,600W | — | 21,000Wh | — | |||||||||
| Pecron F3000LFP | 3,072Wh | 3,600W | No | 9,216Wh | — | |||||||||
| Pecron E3600LFP | 3,072Wh | 3,600W | No | 30,720Wh | — | |||||||||
| EcoFlow Delta 3 Ultra | 3,072Wh | 3,600W | No | — | — | |||||||||
| EcoFlow Delta 3 Ultra Plus | 3,072Wh | 3,600W | No | 11,000Wh | — | |||||||||
| Bluetti Elite 300 | 3,014.4Wh | 2,400W | No | — | — | |||||||||
| Bluetti Apex 300 | 2,764.8Wh | 3,840W | Yes | 58,061Wh | — | |||||||||
| Bluetti Elite 200 V2 | 2,073.6Wh | 2,600W | No | — | — | |||||||||
| Pecron E2400LFP | 2,048Wh | 2,400W | No | 8,192Wh | — | |||||||||
| Anker SOLIX C2000 Gen 2 | 2,048Wh | 2,400W | No | 4,096Wh | — | |||||||||
| EcoFlow Delta 3 Max | 2,048Wh | 2,400W | No | 10,240Wh | — | |||||||||
| EcoFlow Delta 3 Max Plus | 2,048Wh | 3,000W | No | — | — | |||||||||
| Bluetti AC200L | 2,048Wh | 2,400W | No | 8,192Wh | — | |||||||||
| Jackery Explorer 2000 Plus | 2,043Wh | 3,000W | No | 24,516Wh | — | |||||||||
| Jackery Explorer 2000 v2 | 2,042Wh | 2,200W | No | — | — | |||||||||
| Bluetti FridgePower | 2,016Wh | 1,800W | No | — | 4W | |||||||||
| Bluetti AC180 | 1,152Wh | 1,800W | No | — | — | |||||||||
| Anker SOLIX C1000 | 1,056Wh | 1,800W | No | 2,112Wh | — | |||||||||
| EcoFlow Delta 3 Classic | 1,024Wh | 1,800W | No | 5,000Wh | — | |||||||||
| Anker SOLIX C1000 Gen 2 | 1,024Wh | 2,000W | No | — | — | |||||||||
| EcoFlow Delta 2 | 1,024Wh | 1,800W | No | 3,072Wh | — | |||||||||
| EcoFlow Delta 3 | 1,024Wh | 1,800W | No | 5,120Wh | — | |||||||||
| EcoFlow Delta 3 Plus | 1,024Wh | 1,800W | No | 5,120Wh | — | |||||||||
| Bluetti Elite 100 V2 | 1,024Wh | 1,800W | No | — | — |
Of the 38 models we track, the Bluetti FridgePower is the one whose maker publishes self-consumption: 4W (manufacturer Amazon listing ("4W Self-Consumption")). At that draw the 2,016Wh pack would take roughly 21 days to empty itself doing nothing. An 80W idle drain on the same pack — the Solar Lab’s Anker figure — would flatten it in about 25 hours.
1800W covers a standard US wall outlet. 240V is a separate requirement for dryers and water heaters. Runtime is capacity and idle, not the inverter rating. We do not invent a “best home backup” score.
The Solar Lab’s Anker figure is ~80W idle. FridgePower publishes 4W. Those are the idle numbers on this page. The Pecron F5000LFP first-hand write-up is the 12-panel array, not an idle measurement.
Camping carry-weight is on /use/camping/. Fridge-only arithmetic is on /use/refrigerator/. Street-price value is on /value/.
Help improve these comparisons? Optional analytics measures page visits and shopping-link clicks. Privacy details